An evaluation of a 3D multimodal marker-less motion analysis system.
View/ Open
Date
2019-06Author
Rodrigues, Thiago Braga
Rodrigues, Thiago Braga
Ó Catháin, Ciáran
Devine, Declan M.
Moran, Kieran
O'Connor, Noel E.
Murray, Niall
Metadata
Show full item recordAbstract
Motion analysis is a technique used by clinicians (among many
others) that quantifies human movement by using camera-based
systems. Marker-based motion analysis systems have been used
across a variety of application domains, from Interactive 3D Tele-
Immersion (i3DTI) environments to the diagnosis of
neuromuscular and musculoskeletal diseases. Although such
analysis is performed in several laboratories in many countries,
numerous issues exist: (1) the high cost of precise motion capture
systems; (2) scarcity of qualified personnel to operate them; (3)
expertise required to interpret their results; (4) space requirements
to install and store these systems; (5) complexity in terms of
measurement protocol required for such systems; (6) limited
availability; (7) and in some situations the use of markers means
they are unsuitability for certain clinical use cases (e.g. for patients
recovering from orthopaedic surgery). In this paper, we present,
from a system perspective, an alternative, cheaper, and more
accessible system for motion analysis. The ultimate aim is to use
the output of this multimodal marker-less system as part of an
immersive multimedia gait re-education tool. In real-time, it will
advise the user on their gait performance (as well as potentially
providing accurate clinical data to clinicians). With the initial focus
on the capture system, we have developed and evaluated a novel
multimodal system which integrates Multiple Microsoft Kinects
(which employ RGB-D cameras) with multiple Shimmer Inertial
Measurement Unit (IMU) sensors. We have compared this system with the VICON system (the gold standard in motion capture). Our
marker-less motion capture system combines data from 4 skeletons
generating 3D and complete 360 degrees in view skeleton. The
system combines unit quaternions from each Kinect joint with
quaternions from 4 inertial measurement units to promote
integration. We used our system to measure 3D points of 12 joints
from the Kinect fused skeleton and flexion-extension angles of the
knee and hip in a walking trial in 8 participants with 8-10 trials per
participant. The analysis found component similarity of 0.97 for
knee angles and 0.98 for hip angles. These results show that our
system, through combination of Multi Kinect system and Shimmer
IMUs, offers a cheaper, sufficiently accurate and more accessible
human motion analysis system.
Collections