Show simple item record

dc.contributor.authorLodge, Clare
dc.contributor.authorTobin, Diarmuid
dc.contributor.authorO Rourke, Brian
dc.contributor.authorThorborg, Kristian
dc.date.accessioned2023-03-07T10:53:25Z
dc.date.available2023-03-07T10:53:25Z
dc.date.copyright2020
dc.date.issued2019-11-22
dc.identifier.citationLodge, C., Tobin, D., O’Rourke, B., & Thorborg, K. (2020). Reliability and validity of a new eccentric hamstring strength measurement device. Archives of Rehabilitation Research and Clinical Translation, 2(1), 100034. doi:10.1016/j.arrct.2019.100034en_US
dc.identifier.issn2590-1095
dc.identifier.urihttps://research.thea.ie/handle/20.500.12065/4424
dc.description.abstractObjective To investigate the reliability and establish validity of a new eccentric hamstring strength measurement device. Design A randomized double-crossover trial with intraclass correlation coefficients to analyze the outcomes. Participants attended 4 sessions, 7 days apart. They were randomly allocated into 2 groups. Session 1 was a familiarization session for all participants on the new eccentric hamstring strength measurement device and isokinetic dynamometer. The following 3 sessions were used to measure knee flexor (hamstring) eccentric strength on the isokinetic dynamometer and a further test-retest measurement using the new eccentric hamstring strength measurement device. Setting Institute of Technology Carlow, third level educational institution. Participants Male intercollegiate field-sport players completed the trial (N=19). Participants were 21±2 years, weighed 78.6±4.6 kg, and were 179.6±6.4 cm in height. Interventions N/A. Main Outcome Measures Peak torque (Nm) was recorded by the isokinetic device, and peak force (N) was recorded by the new eccentric hamstring strength measurement device and used to test for significant interdevice correlations (>0.7). Intraclass correlation coefficients were calculated using the peak force recorded from 2 separate trials of the new eccentric hamstring strength measurement device. Results High test-retest reliability was observed from the new eccentric hamstring strength measurement device, intraclass coefficient (ICC)=.910 (confidence interval [CI], .76-.96) and .914 (CI, .78-.96) for left and right peak forces, respectively. Typical error of measurement between trials was calculated to be 14.65 and 17.29N for the left and right limbs, respectively. Minimum detectable change (MDC) was also calculated to be 40.62N (MDC%=14.68%) and 39.63N (MDC%=13.31%) for left and right limbs, respectively. The interdevice correlation showed good validity, ICC=.823 (CI, .58-.93) and .840 (CI, .58-.93) for left and right peak torque/forces, respectively. Conclusion(s) The new eccentric hamstring strength measurement device is a reliable and valid device that provides an objective measurement of eccentric hamstring strength that may be used in combination with a comprehensive assessment to inform rehabilitation and management.en_US
dc.formatapplication/pdfen_US
dc.language.isoengen_US
dc.publisherElsevier Incen_US
dc.relation.ispartofArchives of Rehabilitation Research and Clinical Translationen_US
dc.rightsAttribution-NonCommercial-NoDerivs 3.0 Ireland*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/3.0/ie/*
dc.subjectclinical decision-makingen_US
dc.subjecthamstring musclesen_US
dc.subjectrehabilitationen_US
dc.titleReliability and validity of a new eccentric hamstring strength measurement deviceen_US
dc.typeinfo:eu-repo/semantics/articleen_US
dc.description.peerreviewyesen_US
dc.identifier.doihttps://doi.org/10.1016/j.arrct.2019.100034en_US
dc.identifier.issue1en_US
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S2590109519300412en_US
dc.identifier.volume2en_US
dc.rights.accessinfo:eu-repo/semantics/openAccessen_US
dc.rights.accessrightsinfo:eu-repo/semantics/openAccessen_US
dc.subject.departmenthealthCORE- IT Carlowen_US
dc.type.versioninfo:eu-repo/semantics/publishedVersionen_US


Files in this item

Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivs 3.0 Ireland
Except where otherwise noted, this item's license is described as Attribution-NonCommercial-NoDerivs 3.0 Ireland