Show simple item record

dc.contributor.advisorMcGowan, Thaddeusen
dc.contributor.authorCasey, Noelen
dc.date.accessioned2017-03-21T16:00:37Z
dc.date.available2017-03-21T16:00:37Z
dc.date.issued2003
dc.identifier.citationCasey, N. (2003) Sample preconcentration and matrix removal techniques for ultra-trace determinations by inductively coupled plasma mass spectrometry (ICP-MS). PhD, Institute of Technology, Sligoen
dc.identifier.otherPhDen
dc.identifier.urihttps://research.thea.ie/handle/20.500.12065/1435
dc.description.abstractThis thesis describes the design and application of a laboratory-based matrix removal/preconcentration system using an iminodiacetate chelating ion exchange reagent. The chelating ion exchange reagent selectively isolates trace elements in solution from the matrix (macro levels of Ca, Mg, Na and various anions in solution) of analytical samples. This leads to reduced matrix and spectral interferences and improved detection limits for atomic spectrometric determinations. The system is used in conjunction with a low-flow microconcentric nebuliser and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The analytical features of the system are described. These include the pH dependence of analyte recovery, the reproducibility and detection limits achievable by this technique. The system is evaluated for the determination of trace elements in bivalve shells, mineral waters and certified water reference materials. Results of an extensive study profiling trace element constituents in bivalve shells around the Irish coast are presented. The results provide baseline data on the impact of trace element pollution on the Irish marine environment. In particular, the anthropogenic impacts of trace element pollution from the dumping of sewage sludge and dredge material at sea is dicussed.en
dc.formatPDFen
dc.language.isoenen
dc.subjectInductively coupled plasma mass spectrometry.en
dc.subjectIon exchange.en
dc.subjectWater -- Analysis.en
dc.subjectSewage sludge.en
dc.subjectBivalve culture.en
dc.subjectMarine pollution.en
dc.titleSample preconcentration and matrix removal techniques for ultra-trace determinations by inductively coupled plasma mass spectrometry (ISP-MS)en
dc.typeDoctoral Thesisen
dc.publisher.institutionInstitute of Technology, Sligoen
dc.rights.accessCreative Commons Attribution-NonCommercial-NoDerivs CC BY-NC-NDen
dc.subject.departmentEnvironmental Science ITSen


Files in this item

Thumbnail
Thumbnail
Thumbnail
Thumbnail

This item appears in the following Collection(s)

Show simple item record