dc.contributor.advisor | Grennan, Eamonn | en |
dc.contributor.author | Lawlor, Conor | en |
dc.date.accessioned | 2017-03-21T16:01:10Z | |
dc.date.available | 2017-03-21T16:01:10Z | |
dc.date.issued | 2005 | |
dc.identifier.citation | Lawlor, Conor (2005) An investigation into the financial and environmental suitability of ground source heat pumps for residential use in Ireland. M. Sc., Institute of Technology, Sligo. | en |
dc.identifier.other | M Sc taught | en |
dc.identifier.uri | https://research.thea.ie/handle/20.500.12065/1445 | |
dc.description.abstract | A ground source heat pump (GSHP) extracts heat energy from the ground for use in
space and water heating systems. A GSHP requires some electrical energy to operate, but
is capable of extracting up to four times as much heat energy from its source as the initial
electrical energy input.
The purpose of this study is to examine the suitability of ground source heat pumps
(GSHPs) for use in residential heating in Ireland, from certain financial and environmental aspects, as outlined below. Examination of the suitability of GSHPs for use in a group of privately-owned houses found that the optimum array is an array with individual collectors and individual heat
pumps. Though this option was found to be 36% more expensive than an array consisting
of a shared collector and shared heat pump, low running costs and the avoidance of
complications due to shared ownership make the option acceptable in the long term.
Long-term cost comparisons were carried out between GSHPs, natural gas heating and
oil-fired heating systems in a single large (185m2) house. It was found that natural gas
space heating system is 8% cheaper than a GSHP system over a 20 year period. Oil fired
systems are more expensive than both natural gas and GSHP.
A comparison of CO2 emissions from GSHPs, natural gas and oil-fired systems found
that GSHPs are approximately 15% cleaner than the equivalent natural gas system, and
41% cleaner than the oil-fired equivalent.
If there is an accessible seawater source available, it would be the best option as a heat
source, notwithstanding the fact that a corrosion-resistant heat exchanger would be
required. The benefit comes from the fact that an open-loop collector can be utilised, rather than a closed loop system. | en |
dc.format | Pdf | en |
dc.language.iso | en | en |
dc.subject | Dwellings -- Heating and ventilation. | en |
dc.subject | Ground source heat pump systems. | en |
dc.subject | Renewable energy sources -- Ireland. | en |
dc.title | An investigation into the financial and environmental suitability of ground source heat pumps for residential use in Ireland | en |
dc.type | Master Thesis (taught) | en |
dc.publisher.institution | Institute of Technology, Sligo. | en |
dc.rights.access | Creative Commons Attribution-NonCommercial-NoDerivs | en |
dc.subject.department | Dept of Environmental Science, ITS | en |